Condition Monitoring of Flexible Connectors at PTCs

SolarPACES 2025

Authors

DOI:

https://doi.org/10.52825/solarpaces.v4i.2954

Keywords:

Force Analysis, Parabolic Trough Collector, Predictive Maintenance

Abstract

Continuous condition monitoring of critical components in parabolic trough collector (PTC) power plants is crucial for transitioning from traditional reactive maintenance strategies to more efficient predictive maintenance approaches. Predictive maintenance reduces component failures and decreases operation and maintenance costs [1]. The failures and ruptures in flexible pipe connectors PTC can lead to severe consequences, such as leakage and environmental harm [2]. This study focuses on the role of measured forces and torques in enhancing the condition monitoring and maintenance strategies of the flexible pipe connectors. An accelerated life-cycle testing of a set of two connectors until a failure is performed in a test facility. The load cells under the swivel joints are used to measure the forces and torques on the swivel joints. The force analysis was performed and results showed an increase around 5 to 10% in the force amplitude 1000 cycles before the failure. Additionally, the force amplitude increased significantly 200 cycles before the failure. The results proved that the load-based condition monitoring is feasible and effective approach to monitor flexible pipe connectors at PTC.

Downloads

Download data is not yet available.

References

[1] M. Mehos, H. Price, R. Cable, D. Kearney, B. Kelly, G. Kolb, F. Morse. “Concentrating Solar Power Best Practices Study”, Golden, CO: National Renewable Energy Laboratory. NREL/TP-5500-75763, https://www.nrel.gov/docs/fy20osti/75763.pdf (06.07.2026)

[2] G. Saliou, C. Hilgert, R. López-Martín, E. Lüpfert, “Segregation of Influences on Flexible Pipe Connectors (REPA) Force under Field Operation Condition for Parabolic Trough Collector Plants”, Proceedings of SolarPACES, 2021

[3] L. Valenzuela, R. López-Martín, C. M. Amador-Cortés, “Torque in the rotation axis of a parabolic trough solar collector due to wind loads”, SolarPACES 2024 Conference Pro-ceedings, 2024

[4] Objetivos de la PSA como gran instalación solar. https://www.psa.es/es/gen/objetivos.php (05.09.2025)

[5] A. Plumpe, “Design of a Test Rig and its Testing Methods for Rotation and Expansion Performing Assemblies in Parabolic Trough Collector Power Plants”, Master's thesis, RWTH Aachen / DLR Institute of Solar Research, 2016

[6] J. Müller Thore, “Commissioning and validation of the underlying model of a test rig ana-lyzing rotation and expansion performing assemblies in parabolic trough collector power plants”, Master's thesis, RWTH Aachen / DLR Institute of Solar Research, 2017

[7] Kraftsensor K6D175 10kN/1kNm/UP13. https://www.me-systeme.de/de/

k6d175-10kn-1knm (10.03.2025)

[8] A. C. González Alves, “Dynamometer and translational movement improvement for the REPA Test Rig in the Solar Platform of Almeria”, Master's thesis, Universidad de Almería, Escuela Superior de Ingeniería, 2023

Downloads

Published

2026-10-16

How to Cite

Kallio, S., Weiß, J., Schlierbach, A., López-Martín, R., & Lüpfert, E. (2026). Condition Monitoring of Flexible Connectors at PTCs: SolarPACES 2025. SolarPACES Conference Proceedings, 4. https://doi.org/10.52825/solarpaces.v4i.2954

Conference Proceedings Volume

Section

Operations, Maintenance, and Component Reliability
Received 2025-09-16
Accepted 2026-06-05
Published 2026-10-16

Funding data