Phasor Measurement Units, Multi-Criteria Decision Analysis, Power System SecurityAbstract
The deployment of Phasor Measurement Units (PMUs) across transmission and distribution networks offers significant potential for enhancing real-time monitoring, system resilience, and market efficiency. However, the diversity of applications and the associated infrastructure costs necessitate a structured approach to investment prioritization decision-making. This paper presents a hybrid Multi-Criteria Decision Analysis (MCDA) framework to evaluate and rank key PMU use cases. The use cases are first classified across multiple operational dimensions, including location, time domain, data type, and decision horizon. A set of benefit and cost criteria, derived from a review of literature, are used to assess each case. The proposed methodology transforms qualitative assessments into a quantitative decision-making tool, enabling system operators to prioritize PMU deployments based on operational impact, resilience, and cost-effectiveness. Disturbance awareness and voltage stability offer the high operational value with manageable implementation effort.
Downloads
References
[1] D. Novosel and K. Vu, “Benefits of PMU technology for various applications,” presented at the Proceedings of international council on large electric systems-CIGRE croatian na-tional committee, 7th symposium on power system management, Paris, France, 2006, pp. 5–8.
[2] G. Sanchez-Ayala, J. R. Agüerc, D. Elizondo, and M. Lelic, “Current trends on applica-tions of PMUs in distribution systems,” presented at the 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT), IEEE, 2013, pp. 1–6.
[3] S. Skok, I. Ivankovic, and Z. Cerina, “Applications based on PMU technology for im-proved power system utilization,” presented at the 2007 IEEE Power Engineering Society General Meeting, IEEE, 2007, pp. 1–8.
[4] G. Paramo, A. Bretas, and S. Meyn, “Research trends and applications of PMUs,” Ener-gies, vol. 15, no. 15, p. 5329, 2022, doi: 10.3390/en15155329.
[5] K. Martin et al., “An overview of the IEEE standard C37. 118.2—synchrophasor data transfer for power systems,” IEEE Trans. Smart Grid, vol. 5, no. 4, pp. 1980–1984, 2014.
[6] T. L. Saaty, “The analytic hierarchy process for decision in a complex world,” Pittsburgh RWS Publ., 1980.
[7] Y. Li, S. Zhang, Y. Li, J. Cao, and S. Jia, “PMU measurements-based short-term voltage stability assessment of power systems via deep transfer learning,” IEEE Trans. Instrum. Meas., vol. 72, pp. 1–11, 2023.
[8] R. Andreoni, D. Macii, M. Brunelli, and D. Petri, “Tri-objective optimal PMU placement including accurate state estimation: The case of distribution systems,” IEEe Access, vol. 9, pp. 62102–62117, 2021.
[9] J. Zhang, Y. Wang, Y. Weng, and N. Zhang, “Topology identification and line parameter estimation for non-PMU distribution network: A numerical method,” IEEE Trans. Smart Grid, vol. 11, no. 5, pp. 4440–4453, 2020.
[10] E. Shereen, R. Ramakrishna, and G. Dán, “Detection and localization of PMU time syn-chronization attacks via graph signal processing,” IEEE Trans. Smart Grid, vol. 13, no. 4, pp. 3241–3254, 2022.
[11] W. Li, D. Deka, M. Chertkov, and M. Wang, “Real-time faulted line localization and PMU placement in power systems through convolutional neural networks,” IEEE Trans. Power Syst., vol. 34, no. 6, pp. 4640–4651, 2019.
[12] Y. Zhang, J. Wang, and M. E. Khodayar, “Graph-based faulted line identification using micro-PMU data in distribution systems,” IEEE Trans. Smart Grid, vol. 11, no. 5, pp. 3982–3992, 2020.
[13] I. Zenelis, X. Wang, and I. Kamwa, “Online PMU-based wide-area damping control for multiple inter-area modes,” IEEE Trans. Smart Grid, vol. 11, no. 6, pp. 5451–5461, 2020.
[14] A. Aligholian, A. Shahsavari, E. M. Stewart, E. Cortez, and H. Mohsenian-Rad, “Unsu-pervised event detection, clustering, and use case exposition in micro-pmu measure-ments,” IEEE Trans. Smart Grid, vol. 12, no. 4, pp. 3624–3636, 2021.
[15] Y. Liu et al., “Robust event classification using imperfect real-world PMU data,” IEEE Internet Things J., vol. 10, no. 9, pp. 7429–7438, 2022.
[16] H. Mirshekali, R. Dashti, A. Keshavarz, and H. R. Shaker, “Machine learning-based fault location for smart distribution networks equipped with micro-PMU,” Sensors, vol. 22, no. 3, p. 945, 2022, doi: 10.3390/s22030945.
[17] Z. Yang, H. Liu, T. Bi, and Q. Yang, “Bad data detection algorithm for PMU based on spectral clustering,” J. Mod. Power Syst. Clean Energy, vol. 8, no. 3, pp. 473–483, 2020, doi: 10.35833/mpce.2019.000457.
[18] M. Pavlovski, M. Alqudah, T. Dokic, A. A. Hai, M. Kezunovic, and Z. Obradovic, “Hierar-chical convolutional neural networks for event classification on PMU measurements,” IEEE Trans. Instrum. Meas., vol. 70, pp. 1–13, 2021.
[19] Y. Peng, Z. Wu, W. Gu, S. Zhou, and P. Liu, “Optimal micro-PMU placement for improv-ing state estimation accuracy via mixed-integer semidefinite programming,” J. Mod. Power Syst. Clean Energy, vol. 11, no. 2, pp. 468–478, 2022, doi: 10.35833/mpce.2021.000615.
[20] I. F. Azhar, L. M. Putranto, and R. Irnawan, “Development of PMU-based transient stabil-ity detection methods using CNN-LSTM considering time series data measurement,” En-ergies, vol. 15, no. 21, p. 8241, 2022, doi: 10.3390/en15218241.
[21] P. M. Joshi and H. Verma, “Synchrophasor measurement applications and optimal PMU placement: A review,” Electr. Power Syst. Res., vol. 199, p. 107428, 2021, doi: 10.1016/j.epsr.2021.107428.
[22] M. Dashtdar et al., “Fault location in distribution network by solving the optimization prob-lem based on power system status estimation using the PMU,” Machines, vol. 11, no. 1, p. 109, 2023, doi: 10.3390/machines11010109.
[23] S. Liu et al., “Data-driven event detection of power systems based on unequal-interval reduction of PMU data and local outlier factor,” IEEE Trans. Smart Grid, vol. 11, no. 2, pp. 1630–1643, 2019, doi: 10.1109/tsg.2019.2941565.
[24] X. Zheng, B. Wang, D. Kalathil, and L. Xie, “Generative adversarial networks-based syn-thetic PMU data creation for improved event classification,” IEEE Open Access J. Power Energy, vol. 8, pp. 68–76, 2021, doi: 10.17023/4XQ0-9P09.
[25] M.-P. Data, “Situational Awareness in Distribution Grid Using Micro-PMU Data: A Ma-chine Learning Approach”.
[26] A. Abdolahi, N. Taghizadegan, M. R. Banaei, and J. Salehi, “A reliability‐based optimal μ‐PMU placement scheme for efficient observability enhancement of smart distribution grids under various contingencies,” IET Sci. Meas. Technol., vol. 15, no. 8, pp. 663–680, 2021, doi: 10.1049/smt2.12067.
[27] R. Babu, S. Raj, and B. Bhattacharyya, “Weak bus-constrained PMU placement for complete observability of a connected power network considering voltage stability indi-ces,” Prot. Control Mod. Power Syst., vol. 5, no. 4, pp. 1–14, 2020, doi: 10.1186/s41601-020-00174-8.
[28] M. M. Ahmed, M. Amjad, M. A. Qureshi, K. Imran, Z. M. Haider, and M. O. Khan, “A crit-ical review of state-of-the-art optimal pmu placement techniques,” Energies, vol. 15, no. 6, p. 2125, 2022, doi: 10.3390/en15062125.
[29] T. Berghout, M. Benbouzid, and Y. Amirat, “Towards resilient and secure smart grids against Pmu adversarial attacks: a deep learning-based robust data engineering ap-proach,” Electronics, vol. 12, no. 12, p. 2554, 2023, doi: 10.3390/electronics12122554.
[30] A. Ghasemkhani, I. Niazazari, Y. Liu, H. Livani, V. A. Centeno, and L. Yang, “A regular-ized tensor completion approach for PMU data recovery,” IEEE Trans. Smart Grid, vol. 12, no. 2, pp. 1519–1528, 2020.
[31] Y. Yuan, Y. Guo, K. Dehghanpour, Z. Wang, and Y. Wang, “Learning-based real-time event identification using rich real PMU data,” IEEE Trans. Power Syst., vol. 36, no. 6, pp. 5044–5055, 2021, doi: 10.1109/tpwrs.2021.3081608.
[32] N. Taghipourbazargani, G. Dasarathy, L. Sankar, and O. Kosut, “A machine learning framework for event identification via modal analysis of PMU data,” IEEE Trans. Power Syst., vol. 38, no. 5, pp. 4165–4176, 2022, doi: 10.1109/tpwrs.2022.3212323.
[33] D. Dwivedi, P. K. Yemula, and M. Pal, “DynamoPMU: a physics informed anomaly de-tection, clustering, and prediction method using nonlinear dynamics on μ PMU measure-ments,” IEEE Trans. Instrum. Meas., vol. 72, pp. 1–9, 2023, doi: 10.1109/tim.2023.3327481.
[34] B. Appasani, A. V. Jha, S. K. Mishra, and A. N. Ghazali, “Communication infrastructure for situational awareness enhancement in WAMS with optimal PMU placement,” Prot. Control Mod. Power Syst., vol. 6, no. 1, pp. 1–12, 2021, doi: 10.1186/s41601-021-00189-9.
[35] X. Zhu, M. H. Wen, V. O. Li, and K.-C. Leung, “Optimal PMU-communication link place-ment for smart grid wide-area measurement systems,” IEEE Trans. Smart Grid, vol. 10, no. 4, pp. 4446–4456, 2018, doi: 10.1109/tsg.2018.2860622.
[36] M. Zuhaib and M. Rihan, “Identification of low-frequency oscillation modes using PMU based data-driven dynamic mode decomposition algorithm,” IEEE Access, vol. 9, pp. 49434–49447, 2021, doi: 10.1109/access.2021.3068227.
[37] A. S. Dobakhshari, M. Abdolmaleki, V. Terzija, and S. Azizi, “Robust hybrid linear state estimator utilizing SCADA and PMU measurements,” IEEE Trans. Power Syst., vol. 36, no. 2, pp. 1264–1273, 2020, doi: 10.1109/tpwrs.2020.3013677.
[38] S. Basumallik, R. Ma, and S. Eftekharnejad, “Packet-data anomaly detection in PMU-based state estimator using convolutional neural network,” Int. J. Electr. Power Energy Syst., vol. 107, pp. 690–702, 2019, doi: 10.1016/j.ijepes.2018.11.013.
[39] S. Wang, J. Zhao, Z. Huang, and R. Diao, “Assessing Gaussian assumption of PMU measurement error using field data,” IEEE Trans. Power Deliv., vol. 33, no. 6, pp. 3233–3236, 2017, doi: 10.1109/tpwrd.2017.2762927.
[40] G. Frigo, A. Derviškadić, Y. Zuo, and M. Paolone, “PMU-based ROCOF measurements: Uncertainty limits and metrological significance in power system applications,” IEEE Trans. Instrum. Meas., vol. 68, no. 10, pp. 3810–3822, 2019, doi: 10.1109/tim.2019.2907756.
[41] S. Siamak, M. Dehghani, and M. Mohammadi, “Dynamic GPS spoofing attack detection, localization, and measurement correction exploiting PMU and SCADA,” IEEE Syst. J., vol. 15, no. 2, pp. 2531–2540, 2020, doi: 10.1109/jsyst.2020.3001016.
[42] Y. Zhang, J. Wang, and J. Liu, “Attack identification and correction for PMU GPS spoof-ing in unbalanced distribution systems,” IEEE Trans. Smart Grid, vol. 11, no. 1, pp. 762–773, 2019, doi: 10.1109/tsg.2019.2937554.
[43] Z. S. Khalafi, M. Dehghani, A. Khalili, A. Sami, N. Vafamand, and T. Dragičević, “Intru-sion detection, measurement correction, and attack localization of PMU networks,” IEEE Trans. Ind. Electron., vol. 69, no. 5, pp. 4697–4706, 2021, doi: 10.1109/tie.2021.3080212.
[44] W. Ding, M. Xu, Y. Huang, P. Zhao, and F. Song, “Cyber attacks on PMU placement in a smart grid: Characterization and optimization,” Reliab. Eng. Syst. Saf., vol. 212, p. 107586, 2021, doi: 10.1016/j.ress.2021.107586.
Published
How to Cite
Conference Proceedings Volume
Section
License
Copyright (c) 2026 Hamza Bokhari, Ilja Krybus

This work is licensed under a Creative Commons Attribution 4.0 International License.
Accepted 2026-08-13
Published 2026-10-09