Hot Corrosion and Mechanical Performance of Aluminide Coated Austenitic Steel
DOI:
https://doi.org/10.52825/solarpaces.v3i.2389Keywords:
Carbonate Molten Salt, Slurry Aluminide Coating, Austenitic SteelAbstract
The present study aims at improving coatings to allow higher operating temperatures – up to 700 °C – while resisting hot corrosion in future heat transfer fluids and storage systems for CSP technology. An aluminide coating was produced onto a 347H austenitic alloy to resist Li-Na-K molten carbonate corrosion at 700 °C. Multiple surface preparations were investigated and, after optimization, a new diffusion heat treatment was selected. A homogeneous 3-layer coating was formed with Al content reaching up to 69 at.% at the top surface. Corrosion was significantly decreased by the coating compared to the uncoated material. After 500h-exposure, a 100 µm-thick multi-layered and non-adhesive alkali elements rich oxide formed at the surface of uncoated 347H alloy. On the contrary, the coated material preserved its morphology and a mix of α-LiAlO2 and γ-LiAlO2 formed on the top coating. From the mechanical perspective, local hardness measurements highlighted a broad variation along the different layers of the coating. 3-point bending tests showed that deformation in the plastic domain was required to cause crack formation. Cracks remained in the two outermost layers of the coating and did not reach the underneath substrate.
Downloads
References
[1] “REPowerEU: Joint European Action for more affordable, secure and sustainable energy,” Eur. Comm., 2022.
[2] MIT, The future of Energy Storage, vol. 1–3. 2023.
[3] M. Medrano, A. Gil, I. Martorell, X. Potau, and L. F. Cabeza, “State of the art on high-temperature thermal energy storage for power generation. Part 2-Case studies,” Renew. Sustain. Energy Rev., vol. 14, no. 1, pp. 56–72, 2010, doi: 10.1016/j.rser.2009.07.036.
[4] Concentrating solar power: Clean power on demand 24/7. The World Bank, 2020.
[5] P. Audigié et al., “High temperature molten salt corrosion behavior of aluminide and nickel-aluminide coatings for heat storage in concentrated solar power plants,” Surf. Coatings Technol., vol. 349, no. May, pp. 1148–1157, 2018, doi: 10.1016/j.surfcoat.2018.05.081.
[6] C. Prieto, S. Fereres, F. J. Ruiz-Cabañas, A. Rodriguez-Sanchez, and C. Montero, “Carbonate molten salt solar thermal pilot facility: Plant design, commissioning and operation up to 700 °C,” Renew. Energy, vol. 151, pp. 528–541, 2020, doi: 10.1016/j.renene.2019.11.045.
[7] M. Mehos et al., “Concentrating Solar Power Gen3 Demonstration Roadmap,” Golden, CO (United States), Jan. 2017. doi: 10.2172/1338899.
[8] C. S. Turchi, J. Vidal, and M. Bauer, “Molten salt power towers operating at 600–650 °C: Salt selection and cost benefits,” Sol. Energy, vol. 164, no. January, pp. 38–46, 2018, doi: 10.1016/j.solener.2018.01.063.
[9] P. Audigié, V. Encinas-Sánchez, S. Rodríguez, F. J. Pérez, and A. Agüero, “High temperature corrosion beneath carbonate melts of aluminide coatings for CSP application,” Sol. Energy Mater. Sol. Cells, vol. 210, no. March, 2020, doi: 10.1016/j.solmat.2020.110514.
[10] “ASTM A335/A335M-21a - Standard Specification for Seamless Ferritic Alloy-Steel Pipe for High-Temperature Service,” ASTM, 2022.
[11] C. G. Dariva and A. F. Galio, “Corrosion inhibitors: Principles, mechanisms and applications,” in Developments in Corrosion Protection, 2014, pp. 1–161.
[12] J. C. Gomez-Vidal, A. G. Fernandez, R. Tirawat, C. Turchi, and W. Huddleston, “Corrosion resistance of alumina-forming alloys against molten chlorides for energy production. I: Pre-oxidation treatment and isothermal corrosion tests,” Sol. Energy Mater. Sol. Cells, vol. 166, no. February, pp. 222–233, 2017, doi: 10.1016/j.solmat.2017.02.019.
[13] A. Soleimani Dorcheh, R. N. Durham, and M. C. Galetz, “Solar Energy Materials & Solar Cells Corrosion behavior of stainless and low-chromium steels and IN625 in molten nitrate salts at 600 ° C,” Sol. Energy Mater. Sol. Cells, vol. 144, no. 3, pp. 109–116, 2016, doi: 10.1016/j.solmat.2015.08.011.
[14] J. Luo et al., “Corrosion behavior of SS316L in ternary Li2CO3–Na2CO3–K2CO3 eutectic mixture salt for concentrated solar power plants,” Sol. Energy Mater. Sol. Cells, vol. 217, no. September, p. 110679, 2020, doi: 10.1016/j.solmat.2020.110679.
[15] L. González-Fernández, M. Intxaurtieta Carcedo, O. Bondarchuk, and Y. Grosu, “Dynamic Corrosion of Carbonate Salt for 3rd Generation CSP Plants,” SolarPACES Conf. Proc., vol. 1, pp. 1–8, 2024, doi: 10.52825/solarpaces.v1i.614.
[16] Á. G. Fernández and L. F. Cabeza, “Molten salt corrosion mechanisms of nitrate based thermal energy storage materials for concentrated solar power plants: A review,” Sol. Energy Mater. Sol. Cells, vol. 194, no. February, pp. 160–165, 2019, doi: 10.1016/j.solmat.2019.02.012.
[17] P. Audigié et al., “Aluminide slurry coatings for protection of ferritic steel in molten nitrate corrosion for concentrated solar power technology,” AIP Conf. Proc., vol. 1850, 2017, doi: 10.1063/1.4984416.
[18] A. Agüero, P. Audigié, S. Rodríguez, V. Encinas-Sánchez, M. T. De Miguel, and F. J. Pérez, “Protective coatings for high temperature molten salt heat storage systems in solar concentration power plants,” AIP Conf. Proc., vol. 2033, 2018, doi: 10.1063/1.5067095.
[19] M. Akita, Y. Uematsu, T. Kakiuchi, M. Nakajima, and Y. Nakamura, “Effect of Laves Phase Precipitation on Fatigue Properties of Niobium-containing Austenitic Stainless Steel Type 347 in Laboratory Air and in 3%NaCl Solution,” Procedia Mater. Sci., vol. 3, pp. 517–523, 2014, doi: 10.1016/j.mspro.2014.06.086.
[20] “Norma Española UNE-EN ISO 6507-1,” 2018.
[21] A. Agüero, M. Gutiérrez, and V. González, “Deposition process of slurry iron aluminide coatings,” Mater. High Temp., vol. 25, no. 4, pp. 257–265, 2008, doi: 10.3184/096034008X388812.
[22] P. Matysik, S. Józwiak, and T. Czujko, “Characterization of low-symmetry structures from phase equilibrium of Fe-Al system-microstructures and mechanical properties,” Materials (Basel)., vol. 8, no. 3, pp. 914–931, 2015, doi: 10.3390/ma8030914.
[23] J. D. Osorio et al., “Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants,” 2024. [Online]. Available: www.nrel.gov/publications.
[24] S. H. White and U. M. Twardoch, “The solubility and electrochemistry of alkali metal oxides in the molten eutectic mixture of lithium carbonate-sodium carbonate-potassium carbonate,” J. Appl. Electrochem., vol. 19, no. 6, pp. 901–910, 1989, doi: 10.1007/BF01007939.
[25] H. S. Hsu, J. H. DeVan, and M. Howell, “Solubilities of LiFeO2 and (Li, K)2CrO4 in Molten Alkali Carbonates at 650°C,” J. Electrochem. Soc., vol. 134, no. 9, pp. 2146–2150, 1987, doi: 10.1149/1.2100840.
[26] P. Biedenkopf, M. Spiegel, and H. J. Grabke, “The corrosion behavior of Fe-Cr alloys containing Co, Mn, and/or Ni and of a Co-base alloy in the presence of molten (Li,K)-carbonate,” Mater. Corros. - Werkstoffe und Korrosion, vol. 48, no. 11, pp. 731–743, 1997, doi: 10.1002/maco.19970481103.
[27] Y. Zhou et al., “Precipitation behavior of type 347H heat-resistant austenitic steel during long-term higherature aging,” J. Mater. Res., vol. 30, no. 23, pp. 3642–3652, 2015, doi: 10.1557/jmr.2015.343.
[28] J. Luo et al., “Robust corrosion performance of cold sprayed aluminide coating in ternary molten carbonate salt for concentrated solar power plants,” Sol. Energy Mater. Sol. Cells, vol. 237, no. December 2021, p. 111573, 2022, doi: 10.1016/j.solmat.2021.111573.
[29] E. Hamdy, J. N. Olovsjö, and C. Geers, “Perspectives on selected alloys in contact with eutectic melts for thermal storage: Nitrates, carbonates and chlorides,” Sol. Energy, vol. 224, no. October 2020, pp. 1210–1221, 2021, doi: 10.1016/j.solener.2021.06.069.
Published
How to Cite
Conference Proceedings Volume
Section
License
Copyright (c) 2025 Loïc Oger, Alina Agüero, Pauline Audigié

This work is licensed under a Creative Commons Attribution 4.0 International License.
Accepted 2025-04-29
Published 2025-11-18
Funding data
-
European Commission
Grant numbers 101107201 — CoMeTES